Endoform Antimicrobial Restorative Bioscaffold Non-Fenestrated

$19.09   $15.89
Manufacturer: Aroa Biosurgery Limited
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Endoform Antimicrobial Restorative Bioscaffold – Non-Fenestrated

Endoform is an advanced wound care technology that addresses the underlying wound rather than simply managing the symptoms. Advanced extracellular matrix technology provides benefits at each stage of the healing process, helping stabilize, correct, build, and organize tissue in acute and chronic wounds. The composition of Endoform’s natural extracellular matrix enables appropriate interactions with the patient’s cells to aid tissue healing. The Endoform technology is simple to apply and can be used with compression dressings and offloading.

Key Features

  • Contains more than 150 ECM proteins known to be important in wound healing

  • Contains 0.3% ionic silver

  • Provides broad spectrum protection against antimicrobial colonization for up to 7 days

  • Prevents biofilm formation

  • Non-cytotoxic to dermal cells

  • Clinically Tested

Endoform dressings utilize an extracellular matrix (ECM) that helps wounds progress through all healing phases by restoring protease balance. To achieve this, Endorform dressings:

  • Work with and support the body’s existing cells during healing, using a porous ECM structure to do so.
  • Are formulated with residual vascular channels that support the formation of new tissue and blood vessels.
  • Feature a mix of collagen and secondary molecules, including structural and adhesion proteins, and no superfluous substances.
  • Help restructure absent or proliferated proteases.
  • Indicate if protease activity is balanced: Should you continue to see Endoform within the wound bed, the proper ratio has yet to be restored.

Uses

  • Partial and full thickness wounds
  • Pressure ulcers
  • Venous ulcers
  • Diabetic ulcers
  • Chronic vascular ulcers
  • Tunneled/undermined wounds
  • Surgical wounds – donor sites, grafts, post Moh’s surgery, post laser surgery, podiatric wounds, and wound dehiscence
  • Traumatic wounds – abrasions, lacerations, first and second-degree burns, and skin tears
  • Draining wounds
  • Granulating/epithelializing wounds
  • Moderate/highly exudating wounds and non/minimally exudating wounds
  • Can be used in conjunction with compression therapy, off-loading, and negative pressure wound therapy

How to Use Endoform Antimicrobial Restorative Bioscaffold – Non-Fenestrated

  1. Prepare the wound bed by cleansing, irrigating, and if necessary, debridement to remove debris, necrotic tissue, or infected tissue.
  2. Select a sheet of Endoform Antimicrobial which is slightly larger than the wound and apply aseptically. This dressing can be applied as a whole sheet or trimmed so that it contacts the wound margins. Multiple sheets can be used to cover the entire wound bed.
  3. Apply the dressing by placing the dry material in the wound and rehydrating with exudate or sterile saline. When hydrated, Endoform Antimicrobial transforms into a soft conforming sheet. Ensure that the device conforms to the underlying wound bed.
  4. Apply a non-adherent dressing over the device to help protect the tissue while facilitating an optimal moist wound healing environment. 
  5. Secure the device using an appropriate secondary dressing. The secondary dressing should be changed according to standard care and taking into account the level of exudate. 
  6. Duration of treatment and reapplication is determined by the physician and depends upon the wound type and conditions. It is recommended to assess the wound within 72 hours. Reapply when the dressing has been incorporated into the wound. Endoform Antimicrobial may last from 1 day to up to 7 days in the wound, depending on the wound type and environment. Do not attempt to remove the off-white to golden gel that forms from residual Endoform as it contains extracellular matrix components that assist in wound healing. If areas of the device are dry upon inspection, rehydrate with sterile saline and leave in place. It is not necessary to remove any residual Endoform Antimicrobial during dressing changes. 

Contraindications, Warnings, and Precautions

  • Endoform Antimicrobial is derived from an ovine (sheep) source and should not be used on patients with known sensitivity to ovine derived material or ionic silver.
  • Endoform Antimicrobial is not indicated for use on third degree burns
  • Endoform Antimicrobial may be used when visible signs of infection are present in the wound area only when proper medical treatment addresses the underlaying cause. These dressings are not intended to be a substitute for appropriate treatment of infection.
  • Endoform Antimicrobial is terminally sterilized via ethylene oxide. Do not use if the pouch is damaged. Discard the device if mishandling has caused possible damage or contamination. Single use product. Do not re-sterilize. Discard all unused portions. Device reuse may lead to wound infection.
  • Always handle Endoform Antimicrobial using aseptic technique.
  • Do not use past expiry date.
  • Endoform Antimicrobial may cause transient discoloration of the wound bed and surrounding skin. Frequent or prolonged use of this product may result in permanent discoloration of the skin.
  • Endoform Antimicrobial, like other silver-containing products, may darken upon storage, after hydration in saline, when exposed to light, or when in contact with body fluids and tissues. This darkening does not affect product performance. 